PLUMBING
Cols
Summary
Plumbing covers fixtures (water closets, urinals, lavatories, sinks, showers, tubs, and drinking fountains), water heaters, domestic water piping, sanitary and vent piping, floor drains and cleanouts, backflow preventers, and grease interceptors. Systems differ by fixture counts, water use, pipe material, gravity slope and space, accessibility, maintenance, and cost.
Types
- Backflow Preventers
Air gaps, vacuum breakers, double check, and reduced pressure assemblies that keep contaminated water from flowing back into potable water systems. - Domestic Water Piping
Copper, PEX, CPVC, and polypropylene piping that distributes cold and hot potable water from the service to fixtures and equipment. - Drinking Fountains and Bottle Fillers
Wall-mounted and freestanding drinking fountains, electric water coolers, and bottle filling stations, with high-low units for accessibility. - Floor Drains and Cleanouts
Floor drains, floor sinks, trench drains, and cleanouts that collect floor water and give access for clearing drainage piping. - Grease Interceptors
Hydromechanical, gravity, and automatic devices that separate fats, oils, and grease from commercial kitchen waste before it reaches the sewer. - Lavatories and Sinks
Hand-washing lavatories and kitchen, service, and utility sinks with faucets, in vitreous china, stainless steel, enameled cast iron, or solid surface. - Sanitary and Vent Piping
Drain, waste, and vent piping in cast iron, PVC, or ABS that carries wastewater by gravity to the sewer and vents sewer gases. - Sanitary Sewer Connections
The sewer lateral, cleanout, and connection to the public sanitary main, with slope and cover examples, and relocation and abandonment issues. - Showers and Tubs
Prefabricated and site-built shower compartments and bathtubs, with pressure-balancing valves, pan liners, and accessible transfer and roll-in types. - Water Closets and Urinals
Floor-mounted and wall-hung toilets and urinals with tank or flushometer valves, sized by fixture counts and laid out with code and accessibility clearances. - Water Heaters
Storage-tank, tankless, and heat pump water heaters fired by gas or electricity that supply domestic hot water to fixtures and appliances. - Water Service and Meters
The water main tap, service line, curb stop, and meter that bring public water to a building, with ownership splits and relocation issues.
Code reference
Always verify the adopted code edition and local amendments for the project jurisdiction.
Governing editions
| Code or regulation | Edition cited |
|---|---|
| International Plumbing Code (IPC) | 2024 |
| International Energy Conservation Code (IECC) | 2024 (2027 edition due December 2026) |
| 2010 ADA Standards for Accessible Design | 2010 |
Fixture counts and toilet facilities
- IPC 2024, Table 403.1: minimum fixtures by occupancy; for example, business occupancies need water closets at 1 per 25 for the first 50 and 1 per 50 for the remainder, lavatories at 1 per 40 for the first 80 and 1 per 80 for the remainder, and one service sink (water closets and urinals, lavatories and sinks, drinking fountains and bottle fillers)
- IPC 2024, Section 403.1.1: occupant load divided equally between sexes and fractions rounded up; all-gender multiple-user facilities calculated on 100 percent of the occupant load
- IPC 2024, Section 403.1.2: single-user and family or assisted-use rooms count toward required fixtures and are identified for use by all persons
- IPC 2024, Section 403.2: separate facilities by sex except in dwelling units, spaces with 15 or fewer occupants, mercantile with 100 or fewer, business with 25 or fewer, and all-person facilities meeting 403.1.2 or 405.3.4 and 405.3.5
- IPC 2024, Section 403.3.3: public and employee facilities no more than one story above or below the space served, with travel distance 500 ft maximum (300 ft in malls)
- IPC 2024, Section 424.2: urinals may replace up to 67 percent of required water closets in assembly and educational occupancies and up to 50 percent in others (water closets and urinals)
Fixture installation
- IPC 2024, Section 405.3.1: fixtures 15 in. minimum from center to side walls or partitions, 30 in. center to center, 21 in. clear in front; compartments 30 in. by 60 in. (floor-mounted) or 30 in. by 56 in. (wall-hung) (water closets and urinals, lavatories and sinks)
- IPC 2024, Section 405.3.4: each public or employee water closet in a compartment with walls and a door, with exceptions for single-occupant rooms (water closets and urinals)
- IPC 2024, Section 405.3.5: urinal partitions 30 in. apart minimum, from 12 in. or less above the floor to at least 60 in., projecting 18 in. from the wall or 6 in. beyond the urinal lip (water closets and urinals)
- IPC 2024, Sections 425.2 and 425.3: elongated bowls and open-front seats in public and employee facilities (water closets and urinals)
- IPC 2024, Section 410: drinking fountains not required for 15 or fewer occupants; at least two (wheelchair and standing) where required; water dispensers may replace up to 50 percent where three or more are required; none in public restrooms (drinking fountains and bottle fillers)
- IPC 2024, Section 413: floor drains per ASME A112.3.1, ASME A112.6.3, or CSA B79, with removable strainers and outlets 2 in. minimum (3 in. in laundries) (floor drains and cleanouts)
- IPC 2024, Section 421: showers at least 900 sq in. with a 30 in. least dimension; walls waterproof to 72 in. above the floor; pan liners turned up 2 in. above the threshold and sloped 1/4 in. per ft (showers and tubs)
- IPC 2024, Sections 412.3 and 412.5: shower and bathtub valves limited to 120°F (showers and tubs)
- IPC 2024, Section 419.5: tempered water at public lavatories through ASSE 1070 devices (lavatories and sinks)
Water supply
- IPC 2024, Table 604.4: maximum flow: private lavatory and sink faucets 2.2 gpm; public lavatory 0.5 gpm or 0.25 gallon per metering cycle; showerheads 2.0 gpm; urinals 1.0 gallon per flush; water closets 1.6 gallons per flush (all fixtures)
- IPC 2024, Section 604.8: pressure-reducing valve where static pressure exceeds 80 psi (domestic water piping)
- IPC 2024, Section 605.2.1: drinking water components meet NSF 372, 0.25 percent weighted average lead (domestic water piping, drinking fountains and bottle fillers)
- IPC 2024, Tables 605.3 and 605.4: water service and distribution pipe materials, including PEX, CPVC, copper, PP, and PE-RT (domestic water piping)
- IPC 2024, Section 607.1.2: tempered water limited to 110°F by ASSE 1070 devices, ASSE 1017 valves, or listed water heaters (water heaters, lavatories and sinks)
- IPC 2024, Section 607.2: hot water piping 50 ft maximum from source to fixture; commercial buildings follow IECC 2024 Section C404.5 (water heaters, domestic water piping)
Water heaters
- IPC 2024, Section 501.6: tankless heater outlet 140°F maximum for domestic use (water heaters)
- IPC 2024, Section 502.3: attic water heaters need a passage 30 in. high by 22 in. wide, 20 ft maximum length, and 30 by 30 in. service space (water heaters)
- IPC 2024, Sections 504.4 to 504.6: relief valves per ANSI Z21.22, set at 210°F and 150 psi or rated pressure maximum; discharge piping full size, by gravity, ending 6 in. maximum above the floor or receptor (water heaters)
- IPC 2024, Section 504.7: drain pans at least 1-1/2 in. deep with a 3/4 in. drain where leakage could cause damage (water heaters)
Backflow protection
- IPC 2024, Table 608.1: backflow devices and standards by degree of hazard, including RPZ (ASSE 1013), double check (ASSE 1015), pressure vacuum breaker (ASSE 1020), and air gap (ASME A112.1.2) (backflow preventers)
- IPC 2024, Section 608.17: protection of specific connections: boilers, heat exchangers, fire sprinkler systems, lawn irrigation, and beverage dispensers (backflow preventers)
- IPC 2024, Section 312.11: testable backflow assemblies inspected and tested at installation, after repair or relocation, and at least annually (backflow preventers)
Drainage and venting
- IPC 2024, Table 704.1: minimum drainage slope 1/4 in. per ft for 2-1/2 in. and smaller, 1/8 in. per ft for 3 to 6 in., 1/16 in. per ft for 8 in. and larger (sanitary and vent piping)
- IPC 2024, Table 709.1: drainage fixture unit values (sanitary and vent piping)
- IPC 2024, Section 708: cleanouts at 100 ft maximum spacing, at horizontal changes over 45 degrees, and at or within 10 ft upstream of the building drain and sewer junction; clearance 18 in. (6 in. and smaller pipe) or 36 in. (8 in. and larger); not concealed (floor drains and cleanouts)
- IPC 2024, Section 306.2.4: tracer wire (14 AWG minimum insulated copper) for buried plastic sewer pipe (sanitary and vent piping)
- IPC 2024, Sections 312.2 and 312.3: drainage tests with 10 ft of water head or 5 psi air (no air test for plastic) for 15 minutes (sanitary and vent piping)
- IPC 2024, Section 903.5: vent terminals not within 10 ft horizontally of doors, operable windows, or intakes unless 3 ft above them (sanitary and vent piping)
- IPC 2024, Section 918.1: air admittance valves per ASSE 1050 (stack) or ASSE 1051 (individual and branch) (sanitary and vent piping)
Traps and interceptors
- IPC 2024, Section 1002.4: trap seals 2 in. to 4 in.; trap seal protection by ASSE 1018 or ASSE 1044 primers, ASSE 1072 barrier devices, or fixture drain connections (floor drains and cleanouts)
- IPC 2024, Section 1003.3: grease interceptors or automatic grease removal devices for food service fixtures; no food waste disposers to interceptors; no emulsifier or enzyme dispensing; dwelling units exempt (grease interceptors)
- IPC 2024, Section 1003.3.5: hydromechanical interceptors per ASME A112.14.3, ASME A112.14.4, CSA B481, or PDI G101, with Table 1003.3.5.1 grease retention capacity by flow rate (grease interceptors)
- IPC 2024, Section 1003.3.7: gravity interceptors per IAPMO/ANSI Z1001, sized at peak drain flow times 30 minutes retention (grease interceptors)
Accessibility
- 2010 ADA Standards, Section 602: drinking fountain spouts 36 in. maximum (wheelchair) and 38 in. to 43 in. (standing) (drinking fountains and bottle fillers)
- 2010 ADA Standards, Section 604: water closets 16 to 18 in. from the side wall, seats 17 to 19 in., wheelchair compartments 60 in. wide by 56 in. (wall-hung) or 59 in. (floor-mounted) deep, ambulatory compartments 35 to 37 in. wide (water closets and urinals)
- 2010 ADA Standards, Section 605: urinal rims 17 in. maximum above the floor (water closets and urinals)
- 2010 ADA Standards, Section 606: lavatory and sink rims 34 in. maximum, forward approach with knee and toe clearance, pipes insulated (lavatories and sinks)
- 2010 ADA Standards, Section 608: transfer showers 36 by 36 in., roll-in 30 by 60 in. or 36 by 60 in., hand shower hose 59 in., water 120°F maximum, thresholds 1/2 in. (showers and tubs)
Referenced standards
| Standard | Edition | Required by | Applies to |
|---|---|---|---|
| ASME A112.19.2/CSA B45.1 | Latest adopted | IPC 2024, 419, 424, 425 | Ceramic fixtures |
| ASME A112.18.1/CSA B125.1 | Latest adopted | IPC 2024, 412.1 | Faucets and fittings |
| ASSE 1016/ASME A112.1016 | Latest adopted | IPC 2024, 412.3 | Shower valves |
| ASSE 1070 | Latest adopted | IPC 2024, 412.5, 419.5, 607.1.2 | Temperature limiting devices |
| NSF 61 / NSF 372 | Latest adopted | IPC 2024, 605.2, 605.2.1 | Drinking water components |
| ANSI Z21.22 | Latest adopted | IPC 2024, 504.4 | Water heater relief valves |
| ASSE 1013 / 1015 / 1020 / 1024 | Latest adopted | IPC 2024, Table 608.1 | Backflow preventers |
| ASTM A888 / CISPI 301 / ASTM D2665 / ASTM D2661 | Latest adopted | IPC 2024, Table 702.1 | DWV pipe |
| ASSE 1050 / 1051 | Latest adopted | IPC 2024, 918.1 | Air admittance valves |
| ASSE 1018 / 1044 / 1072 | Latest adopted | IPC 2024, 1002.4.1 | Trap seal protection |
| ASME A112.14.3 / A112.14.4 / CSA B481 / PDI G101 / IAPMO Z1001 | Latest adopted | IPC 2024, 1003.3 | Grease interceptors |
Sources
- UpCodes: 2024 IPC Chapter 3 general regulations (GSA adoption without amendments), https://up.codes/viewer/general-services-administration/ipc-2024/chapter/3/general-regulations
- UpCodes: 2024 IPC Chapter 4 fixtures, faucets, and fixture fittings, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/4/fixtures-faucets-and-fixture-fittings
- UpCodes: 2024 IPC Chapter 5 water heaters, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/5/water-heaters
- UpCodes: 2024 IPC Chapter 6 water supply and distribution, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/6/water-supply-and-distribution
- UpCodes: 2024 IPC Chapter 7 sanitary drainage, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/7/sanitary-drainage
- UpCodes: 2024 IPC Chapter 9 vents, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/9/vents
- UpCodes: 2024 IPC Chapter 10 traps, interceptors, and separators, https://up.codes/viewer/general-services-administration/ipc-2024/chapter/10/traps-interceptors-and-separators
- Corada: 2010 ADA Standards Sections 602 to 608, https://www.corada.com/documents/2010ADAStandards/604