IBC Occupancy Classification


Summary

Occupancy classification assigns each use in a building to one of the IBC's groups (A, B, E, F, H, I, M, R, S, U) based on what people do there and how hazardous the contents are. It is the first decision in a code review, because the group drives construction type, height and area limits, separations, sprinklers, and egress.


Cols

Scope

Terminology

Classification

Groups and uses

Group Section Use
A-1 303.2 Fixed-seat assembly for the performing arts or motion pictures
A-2 303.3 Assembly for food and drink: restaurants, bars, nightclubs
A-3 303.4 Worship, recreation, amusement, and other assembly not in another A group
A-4 303.5 Indoor viewing of sporting events with spectator seating
A-5 303.6 Participation in or viewing of outdoor activities: stadiums, grandstands, bleachers
B 304.1 Office, professional, or service-type transactions; also outpatient clinics, training not in a school, and education above the 12th grade
E 305.1 Six or more persons at one time for education through the 12th grade; day care for more than five children older than 2-1/2 years
F-1 306.2 Moderate-hazard factory and industrial uses not classified F-2
F-2 306.3 Low-hazard factory uses that fabricate noncombustible materials
H-1 307.3 Detonation hazard
H-2 307.4 Deflagration or accelerated burning hazard
H-3 307.5 Materials that readily support combustion or pose a physical hazard
H-4 307.6 Health hazards: corrosive, toxic, highly toxic
H-5 307.7 Semiconductor fabrication and comparable research using hazardous production materials
I-1 308.2 More than 16 persons, excluding staff, living 24 hours a day in a supervised environment with custodial care
I-2 308.3 24-hour medical care for more than five persons incapable of self-preservation
I-3 308.4 More than five persons under restraint or security
I-4 308.5 Custodial care for more than five persons of any age for less than 24 hours a day
M 309.1 Display and sale of merchandise with public access
R-1 310.2 Transient lodging: hotels and motels, and boarding houses with more than 10 occupants
R-2 310.3 Permanent occupancy: apartments, dormitories, nontransient hotels and motels with more than five guestrooms
R-3 310.4 Not more than two dwelling units, and small care and boarding uses
R-4 310.5 More than five but not more than 16 persons, excluding staff, in 24-hour care
S-1 311.2 Moderate-hazard storage not classified S-2
S-2 311.3 Low-hazard storage of noncombustible materials
U 312.1 Accessory and miscellaneous structures: private garages, carports, sheds, barns, retaining walls, fences over 7 ft, towers, tanks

Where the line falls

Worked examples

Four-story mixed-use building

Space Use Group Reason
Ground-floor restaurant, 4,500 sq ft with tables and chairs Food and drink A-2 Section 303.3; 4,500 ÷ 15 = 300 occupants, well above 50
Ground-floor retail shop Sale of merchandise M Section 309.1
Second-floor offices Professional transactions B Section 304.1
Floors 3 and 4, 24 apartments Permanent residence R-2 Section 310.3
Below-grade resident parking Private vehicle storage S-2 Section 311.3
Rooftop storage shed Accessory structure U Section 312.1

Five different groups put the building in the mixed-occupancy provisions; the separation, sprinkler, and height and area checks follow.

Small meeting room

A 600 sq ft conference room with 40 people at tables is accessory to an office suite.

Step Calculation Result
Floor area 600 sq ft Under the 750 sq ft threshold
Occupant load 600 ÷ 15 = 40 persons Under 50
Classification Sections 303.1.1 and 303.1.2 Group B, or part of the office occupancy

If the room grew to 800 sq ft for 60 people, both thresholds are exceeded and it becomes an assembly space (Group A-3 for a meeting room), with its own egress, sprinkler, and separation analysis.

Coordination

Common issues

Standards

Sources