SITE ELEMENTS
Cols
Summary
Site Elements covers the constructed and planted parts of the site outside the building envelope and the strategy for arranging them: drainage, paving, decks, retaining walls, lighting, pipe bedding, planting, hardscape, water features, grading, irrigation, and soils. Strategy notes respond to climate and site, while element notes cover assemblies, structural role, drainage, exposure, and power and photometric requirements; rainwater harvesting has its own parent.
Types
- Defensible Space
The zoned approach to defensible space around a building, from the ember-resistant zone at the walls out to a reduced-fuel zone. - Exterior Decking
Wood and plastic composite deck framing and surfaces, with ledger, footing, lateral connection, guard, and fastener issues that decide deck safety. - Grading and Stormwater Strategy
Site grading and on-site stormwater strategy, including rain gardens, bioswales, and permeable pavement, and how they relate to building foundations. - Hardscape Design
Design of paved and built site surfaces, with base design, edge restraint, and moisture and freeze-thaw considerations for interlocking pavers. - Irrigation
Landscape irrigation system choices, including drip, spray, and weather-based controllers, and the water savings each offers. - Landscaping and Planting
Trees, shrubs, lawns, and planting beds as installed elements, covering planting soil, nursery stock standards, planting depth, and mulch. - Planting Strategies
Using plant selection, layering, and placement to shade, shelter, and screen buildings while matching plants to climate and water supply. - Retaining Walls
Walls that hold back soil at grade changes, including cantilever concrete, gravity, segmental block, gabion, and soldier pile walls, used for sites, foundations, and landscapes. - Site and Pole Lighting
Pole-mounted area, roadway, and pedestrian LED luminaires, plus bollards and landscape lights, used to light parking lots, drives, walkways, and building sites. - Site Drainage
Grading, swales, French drains, area drains, drywells, and storm piping that move surface and subsurface water away from buildings and off the site. - Site Paving
Asphalt, concrete, and unit paver surfaces for drives, parking, and walks, with base design, thickness, slope, and edge restraint. - Soils and Site Preparation
Evaluating site soils with the NRCS Web Soil Survey and field checks, and preparing soils for planting, paving, and infiltration. - Vegetated Roofs
Roof assemblies with waterproofing, drainage, growing medium, and plants, used for stormwater retention, heat reduction, amenity space, and membrane protection. - Water Features
Fountains, pools, and other recirculating water features, with turnover and flow-rate sizing, filtration, and disinfection basics. - Wildland-Urban Interface Planting
Plant selection, spacing, and mulch rules for landscapes in the wildland-urban interface, organized by distance from the building.
Code reference
Always verify the adopted code edition and local amendments for the project jurisdiction.
Governing editions
| Code or regulation | Edition cited |
|---|---|
| International Building Code (IBC) | 2024 |
| International Energy Conservation Code (IECC) | 2024 |
| International Plumbing Code (IPC) | 2024 |
| International Residential Code (IRC) | 2024 |
| 2010 ADA Standards for Accessible Design | 2010 |
Retaining walls
- IBC 2024, Section 1807.2.1: retaining walls designed against overturning, sliding, excessive foundation pressure, and water uplift (retaining walls)
- IBC 2024, Section 1807.2.2: lateral soil loads per Section 1610; in Seismic Design Category D, E, or F, walls retaining more than 6 ft of backfill include seismic lateral earth pressure from the geotechnical investigation (retaining walls)
- IBC 2024, Section 1807.2.3: factor of safety 1.5 against sliding and overturning; 1.1 where earthquake loads are included (retaining walls)
- IBC 2024, Section 1807.2.4: dry-cast segmental retaining wall units comply with ASTM C1372 (retaining walls)
Exterior lighting
- IECC 2024, Section C405: exterior lighting power allowances and controls for site and pole lighting (site and pole lighting)
Site grading and drainage
- IBC 2024, Section 1804.3: backfill free of organic material, construction debris, cobbles, and boulders, or controlled low-strength material (CLSM); placed in lifts without damaging foundations or waterproofing; CLSM needs no compaction (site drainage, pipe bedding)
- IBC 2024, Section 1804.4: slope the ground next to the foundation away from the building at 1 in 20 (5 percent) for at least 10 ft; swales within 10 ft of the foundation at least 2 percent; impervious surfaces within 10 ft at least 2 percent away from the building; finished floor at least 6 in. above finished grade at the building perimeter; account for backfill settlement; grading and runoff must not harm surrounding sites (site drainage, site paving)
- IBC 2024, Section 1804.6: shallow foundations on compacted fill follow a geotechnical report, except fill 12 in. deep or less at 90 percent of maximum dry density per ASTM D1557, with special inspection per Section 1705.6 (site paving)
- IPC 2024, Section 1101.2: roof, paved-area, yard, and court storm water drains to an approved disposal point; one- and two-family dwellings may discharge onto flat areas such as streets or lawns if flow is away from the building (site drainage)
- IPC 2024, Sections 1101.3 and 1104.2: storm water not drained to sanitary-only sewers; floor drains not connected to storm drains (site drainage)
- IPC 2024, Sections 1101.5, 1101.8, and 1101.9: storm pipe size not reduced in the direction of flow; cleanouts required (subsurface drainage exempt); backwater valves per Section 714 (site drainage)
- IPC 2024, Tables 1102.4 and 1102.5: building storm sewer and subsoil drain pipe materials; subsoil pipe open-jointed, horizontally split, or perforated (site drainage, pipe bedding)
- IPC 2024, Section 1106.1: conductors, leaders, building storm drains, and storm sewers sized for the 100-year, 1-hour rainfall rate or approved local data (site drainage)
- IPC 2024, Section 1111.1: subsoil drains at least 4 in. diameter; accessible backwater valve where backwater can occur; discharge to a trapped area drain, sump, dry well, or approved location above ground (site drainage)
- IPC 2024, Section 1113.1.2: sump pit at least 18 in. diameter and 24 in. deep with access, gravity drainage to the pit, and a removable cover (site drainage)
Trenching and backfill
- IPC 2024, Sections 306.1 and 306.2: buried piping supported along its full length; solid continuous bearing between joints; bell holes at each joint; no blocks on grade; manufacturer instructions govern if more restrictive (pipe bedding)
- IPC 2024, Sections 306.2.1 to 306.2.3: overexcavation backfilled with sand or fine gravel in layers no more than 6 in. and compacted; rock removed at least 3 in. below the pipe; soft bearing material overexcavated at least two pipe diameters and backfilled with fine gravel, crushed stone, or concrete on tamped sand (pipe bedding)
- IPC 2024, Section 306.2.4: tracer wire, 14 AWG minimum with direct-burial insulation, for buried plastic sewer pipe (pipe bedding)
- IPC 2024, Section 306.3: debris-free backfill placed in 6 in. layers and tamped until the crown is covered by 12 in. of tamped earth (pipe bedding)
Decks
- IRC 2024, Section R507.1: wood-framed decks designed for the greater of the live load in Section R301.5 or the ground snow load (exterior decking)
- IRC 2024, Section R507.2: wood decay and termite protection with No. 2 or better sawn lumber; plastic composite boards, treads, guards, and handrails to ASTM D7032 with labeling and flame spread index not exceeding 200 (ASTM E84 or UL 723); fasteners hot-dipped or mechanically galvanized or stainless steel, stainless within 300 ft of salt water; flashing corrosion-resistant metal at least 0.019 in. thick (exterior decking)
- IRC 2024, Sections R507.3 and R507.4: concrete footings sized by Table R507.3.1, at least 12 in. below undisturbed ground and below the frost line, with exemptions for small free-standing decks; post height per Table R507.4 and post-to-footing lateral restraint (exterior decking)
- IRC 2024, Sections R507.5 to R507.7: beams per Tables R507.5(1) to (4); joists at 12, 16, or 24 in. per Table R507.6 with L/360 and L/180 deflection limits and 1-1/2 in. bearing on wood; wood decking spacing per Table R507.7 (exterior decking)
- IRC 2024, Sections R507.8 and R507.9: positive attachment to the building, not by toenails or withdrawal-loaded nails; ledger at least 2x8 in. fastened per Tables R507.9.1.3(1) and (2) and not on masonry veneer; ledger flashing, water-resistive barrier lap, and a lateral connection by two 1,500 lb hold-downs or four 750 lb hold-downs (exterior decking)
- IRC 2024, Section R507.10: exterior guards with a continuous load path to the joists; 4x4 guard posts not notched; composite guards per R507.2.2 (exterior decking, guards and railings)
Accessible routes
- 2010 ADA Standards, Section 403.3: walking surface running slope not steeper than 1:20 and cross slope not steeper than 1:48 (site paving)
- 2010 ADA Standards, Section 403.5: clear width 36 in. minimum, with limited reductions to 32 in.; passing spaces 60 in. by 60 in. at 200 ft maximum intervals where width is under 60 in. (site paving)
Referenced standards
| Standard | Edition | Required by | Applies to |
|---|---|---|---|
| ASTM C1372, segmental retaining wall units | Latest adopted | IBC 2024, 1807.2.4 | Retaining walls |
| ASTM D1557 | Latest adopted | IBC 2024, 1804.6 | Site paving |
| ASTM D7032 | Latest adopted | IRC 2024, R507.2.2 | Exterior decking |
| ASTM E84 / UL 723 | Latest adopted | IRC 2024, R507.2.2.2 | Exterior decking |
| FGIA 711 | Latest adopted | IRC 2024, R507.2.4 | Exterior decking |
Sources
- UpCodes: 2024 IPC Chapter 11 storm drainage and Chapter 3 general regulations (GSA adoption without amendments), https://up.codes/viewer/general-services-administration/ipc-2024/chapter/11/storm-drainage
- UpCodes: 2024 IRC Chapter 5 floors, Section R507, https://up.codes/viewer/general-services-administration/irc-2024/chapter/5/floors
- Corada: 2010 ADA Standards Section 403, https://www.corada.com/documents/2010ADAStandards/403
- UpCodes: 2024 IBC Chapter 18 soils and foundations, https://up.codes/viewer/department-of-defense/ibc-2024/chapter/18/soils-and-foundations
- Rutgers Cooperative Extension: energy-efficient landscaping, https://greenmanual.rutgers.edu/nr-energy-efficient-landscaping/
- U.S. EPA: WaterSense irrigation controllers, https://epa.gov/watersense/irrigation-controllers