Ramps, Stairs, and Elevators


Summary

Accessible vertical circulation uses ramps no steeper than 1:12, stairs with uniform risers and handrails, and elevators or lifts sized for a wheelchair, with landings and handrail extensions at every change. The ramp length, landing, and elevator car sizes occupy large areas of plan, so size them with the first floor plans.


Cols

Scope

Terminology

Requirements

Ramps

Stairs and handrails

Elevators

Door arrangement Door clear width Car inside (side to side by back to door face)
Centered 42 in. 80 in. by 54 in.
Off-center 36 in. 68 in. by 54 in.
Other configurations 36 in. 54 in. or 60 in. by 80 in. or 60 in.

Worked examples

Ramp length

A building entrance is 24 in. above the sidewalk.

Step Calculation Result
Maximum rise per run 30 in. 24 in. is one run
Run length at 1:12 24 × 12 288 in. = 24 ft
Landings Top 60 in., bottom 60 in. Add 5 ft each end
Total length 24 + 5 + 5 34 ft
Handrails Rise over 6 in. Both sides, extended 12 in. at each end

Two-run ramp

A floor is 54 in. above grade.

Step Calculation Result
Runs 54 ÷ 30 → at least two runs Two runs of 27 in. each
Run length 27 × 12 324 in. = 27 ft each
Turn landing 60 in. by 60 in. Between the runs
Layout Two 27 ft runs plus landings A switchback keeps the footprint compact

Elevator car

A centered-door elevator with a 42 in. door.

Step Check Result
Door 42 in. clear Meets Table 407.4.1 centered
Car 80 in. by 54 in. inside Shaft must be larger by wall, rail, and equipment clearances from the vendor
Door open time Hall call distance D = 20 ft, T = 20 ÷ 1.5 13.3 s

Coordination

Common issues

Standards