Height and Story Limits


Summary

Zoning sets a maximum building height in feet, a maximum number of stories, or both, and defines exactly where height is measured from and to. The measurement method can move a design by several feet, so confirm how grade and roof height are defined before setting floor-to-floor heights.


Cols

Scope

Terminology

Requirements

Measuring height

Exceptions

Stories

Worked examples

Pitched roof

An illustrative district limit of 35 ft, measured to the mean roof height of a gable roof from average finished grade.

Step Calculation Result
Eave height 24 ft above average grade 24 ft
Ridge height 38 ft above average grade 38 ft
Mean roof height (24 + 38) ÷ 2 31 ft
Check 31 ft against 35 ft Complies; the ridge may exceed 35 ft

Flat roof

The same district limit measured to the coping of a flat roof.

Step Calculation Result
Floor-to-floor height 12 ft × 3 stories 36 ft
Parapet 3 ft above the roof 39 ft to the top of the parapet
Check 39 ft against 35 ft Exceeds the limit
Fix Reduce floor-to-floor to 10 ft 6 in. 31.5 ft + 3 ft parapet = 34.5 ft

Rooftop equipment

Step Check Result
Mechanical equipment on a 38 ft building in a 40 ft district Ordinance allows equipment up to 10 ft above the maximum height Equipment may reach 50 ft above grade, subject to the ordinance's screening and setback rules
Roof area covered 5 percent of the roof area in some codes 1,000 sq ft roof allows 50 sq ft of non-habitable projections

Coordination

Common issues

Standards

Sources