Accessible Controls, Counters, and Work Surfaces


Summary

Public counters, check-out aisles, tables, work surfaces, and benches must have a section at a lower height with knee clearance, in numbers set by scoping. Lowering part of a counter changes millwork, so program the accessible portions with the casework design.


Cols

Scope

Terminology

Requirements

Dining and work surfaces

Sales and service counters

Benches

Communication

Worked examples

Restaurant seating

A restaurant has 80 dining seats and 20 standing spaces at a bar.

Step Calculation Result
Total seating and standing spaces 80 + 20 100
Accessible 100 × 0.05 5 spaces at 28 in. to 34 in. high
Distribution Each type and area Spread across the dining area and the bar

Check-out aisles

A grocery store has 12 check-out aisles, all for the same function.

Step Requirement Result
Aisles 9 to 15 3 accessible
Height 38 in. maximum counter Lower the accessible aisle counters
Store under 5,000 sq ft selling space Exception One accessible aisle at most

Reception counter

A reception counter is 10 ft long.

Step Requirement Result
Accessible portion 36 in. high maximum, 36 in. long minimum parallel A 36 in. lowered section
Forward approach option 30 in. long with knee clearance Open knee space below

Coordination

Common issues

Standards