Rainwater Pumps and Distribution
Summary
Rainwater distribution delivers stored water to fixtures and irrigation by gravity or by a pump, with make-up water for dry periods. Delivery pressure, make-up supply, and separation from the potable system decide the pump, controls, and piping, so they are coordinated with the plumbing engineer.
Cols
Terminology
- Gravity delivery: pressure from the height of the storage above the outlet
- Booster pump / pressure set: pump that supplies pressure when gravity is not enough
- Pressure-reducing valve: limits static pressure in the system
- Make-up water: potable or reclaimed supply that refills the tank at a low level
- Air gap: open space that separates the make-up supply from the water level
- Nonpotable outlet: hose bibb, faucet, or open pipe carrying nonpotable water
- Dual plumbing: separate potable and nonpotable piping in a building
Standards
- Pressure by height: the greater the vertical difference between storage and outlet, the greater the pressure
- Pressure by use: showering needs much more pressure than drip irrigation
- Pumps: needed only where the system is pressurized
- Code provisions: pump access, pressure limits, make-up water, backflow protection, pipe identification, signage, and testing are in the plumbing code reference
- Backflow: make-up connections and any connections to potable systems use backflow protection
Components
- Pump set: submersible or surface pump with pressure tank or variable speed control
- Controls: float switches or level sensors that stop the pump at low level and call make-up water
- Make-up valve and line: with an air gap and a full-open shutoff on the make-up line
- Filters: upstream of the pump and at the point of use
- Pressure-reducing valve: where pump pressure exceeds the allowed static pressure
- Distribution piping: identified and separate from potable piping
- Signage: at each nonpotable outlet
- Locked outdoor outlets: hose connections in a locked vault or requiring a removable key
Detailing
- Separation: keep distribution piping apart from potable piping and building sewers as the code requires
- Access: removable access for pumps, valves, and filters
- Protect the pump: water must not fall below the pump intake; automatic make-up valves hold a minimum level
- Place the pump room: near the tank, drained, and heated or insulated where freezing occurs
- Identify piping: labels or color per code at regular intervals and at every outlet
- Test: pressure test the make-up and distribution piping before use
- Document: provide an O&M manual with schematic, parts list, and maintenance schedule
Uses
Specific uses
- Toilet and urinal flushing
- Irrigation systems
- Cold water laundry
- Vehicle and equipment washing
Pros and cons
Pros
- Gravity delivery from an elevated tank needs no pump
- A packaged pump set is a standard plumbing product
- Make-up water keeps flushing running through dry periods
Cons
- Pumps need power and maintenance
- Dual piping and signage add cost and coordination
- Make-up supply needs backflow protection and an air gap
Manufacturing and cost
Construction
- Packaged pump sets with controls and a pressure tank or variable speed drive, installed with filters and a make-up valve
Main manufacturers and suppliers
Trade association: ARCSA, American Rainwater Catchment Systems Association.