NEC Branch Circuits and Receptacles


Summary

The NEC sets how many receptacle outlets a dwelling needs and how far apart they go, requires dedicated small-appliance circuits in kitchens, and requires ground-fault and arc-fault protection in listed locations. Receptacle layout and protected locations show on every residential electrical plan, and the 2026 edition changes several of them.


Cols

Scope

Terminology

Requirements

Receptacle outlets in dwellings

GFCI and AFCI protection

Worked examples

Living room spacing

Wall Check Result
14 ft wall with no openings One receptacle at the center leaves the ends 7 ft away, more than 6 ft At least two receptacles, each end within 6 ft of one
Spacing between receptacles No point more than 6 ft from a receptacle Receptacles about 12 ft apart or closer
12 ft wall with a 3 ft doorway in the middle A doorway splits the wall into separate wall spaces Each wall space of 2 ft or more is checked on its own

Kitchen circuits

Step Rule Result
Small-appliance circuits At least two 20 A circuits Two circuits serving countertop outlets
Countertop receptacles Each wall counter space 12 in. or wider A 24 in. counter run needs at least one
Island with a counter 2026: none within 24 in. below the countertop surface Install receptacles on the wall or in a pop-up unit
Other loads No other outlets on small-appliance circuits Separate circuits for lighting, dishwasher, disposal

GFCI and AFCI check

Location Protection to check
Bathroom basin Outlet within 3 ft of the basin, GFCI protected
Outdoor outlet GFCI protected up to 60 A in 2026
Outdoor HVAC outlet Class A, HF Class A, or Class C SPGFCI