Every sleeping room, basement, and habitable attic in a house needs at least one operable opening of a minimum clear size and maximum sill height that leads to a yard or public way, with window wells sized to let it open fully. The size is measured after normal operation of the window, so the window type and sash choice decide whether a bedroom or basement qualifies.


Cols

Scope

Terminology

Requirements

Where required

Size and height

Dimension Requirement Section
Net clear opening 5.7 sq ft R319.2.1
Net clear opening, grade floor 5 sq ft R319.2.1
Net clear height 24 in. R319.2.2
Net clear width 20 in. R319.2.2
Sill height 44 in. maximum above the floor R319.2.3

Window wells

Replacements and additions

Worked examples

Window size check

A window opens to a clear 24 in. high by 30 in. wide after normal operation.

Step Calculation Result
Clear area 24 × 30 = 720 sq in. ÷ 144 5.0 sq ft
Height and width 24 in. and 30 in. Meets 24 in. and 20 in.
Area, grade floor 5.0 sq ft Meets the 5 sq ft grade floor minimum
Area, above or below grade 5.0 sq ft Fails the 5.7 sq ft minimum

Sill height check

A bedroom window's clear opening has a bottom edge 40 in. above the floor and the top edge 70 in. above the floor.

Step Calculation Result
Sill height 40 in. against 44 in. maximum Meets the limit
Clear height 70 − 40 30 in., meets the 24 in. minimum
Required width for 5.7 sq ft 5.7 × 144 ÷ 30 27.4 in. minimum clear width

Basement window well

An opening has its sill 6 ft below grade.

Step Check Result
Well size 36 in. by 36 in. 9 sq ft, meets the minimum
Depth 72 in. is over 44 in. Permanent ladder or steps required
Ladder Rungs at most 18 in. on center At least 4 rungs for a 72 in. depth
Drainage Poorly drained soil Connect to foundation drainage

Coordination

Common issues

Standards