MINERALS
Cols
Summary
Mineral material notes covering binders (cement, lime, plaster, mortar, grout), concrete and its components (fly ash, slag, cast stone, autoclaved aerated concrete), clay products (clay, terra cotta, ceramic and porcelain), glass, gypsum, stone, and mineral insulation and boards (mineral wool, perlite, vermiculite, calcium silicate, magnesium oxide board). Code provisions for concrete, masonry, glass, and gypsum and plaster sit in the Code reference below.
Types
- Autoclaved Aerated Concrete
Lightweight, cellular precast concrete cured in an autoclave, supplied as blocks and panels for walls. - Bedrock
Solid rock beneath loose surface material, the strongest foundation bearing stratum when found at reachable depth. - Calcium Silicate
Hydrated calcium silicate board with fibers, used as a noncombustible, moisture-resistant lining and fire-protection board. - Cast Stone
Precast concrete made to imitate natural stone, used for trim, sills, copings, and facing. - Cement
Fine hydraulic binder, mostly portland cement clinker ground with gypsum, used in concrete, mortar, grout, plaster, and terrazzo. - Ceramic and Porcelain
Fired clay bodies, glazed or unglazed, used for tile, with porcelain fired hotter and denser than other ceramics. - Clay
Fine-grained earth, fired into brick, tile, and terra cotta, used for masonry walls, veneer, paving, roofing, and sanitary ware. - Concrete
Composite of aggregate bound by hydrated cement paste, placed cast-in-place or precast for foundations, slabs, walls, frames, and masonry units. - Fiber Cement
Portland cement matrix reinforced with cellulose or other non-asbestos fibers, formed into siding, panels, planks, and backer boards. - Fly Ash
Fine glassy coal combustion residue used as a supplementary cementitious material and as a cement replacement in concrete. - Glass
Transparent, brittle soda-lime silicate material made by the float process, used for windows, doors, curtain wall, and glazing. - Grout
Fluid cement or resin mix that fills tile joints, masonry cells, and voids under plates and anchors. - Gypsum
Hydrated calcium sulfate mineral, calcined to plaster and pressed into board, used for interior wall and ceiling lining, plaster, and fire-rated assemblies. - Lime
Calcium oxide and calcium hydroxide made by burning limestone, used for plaster, mortar, and stucco. - Magnesium Oxide Board
Fiberglass-faced board of magnesium oxide cement, used for fire-resistive and moisture-resistant sheathing and lining. - Mineral Wool
Spun fibers of rock or slag, supplied as batts and boards for thermal, acoustic, and fire-resistive insulation. - Mortar
Cement, lime, sand, and water mix that bonds masonry units and fills joints, graded by type M, S, N, O, and K. - Perlite
Volcanic glass expanded by heat into a lightweight, white aggregate for plaster, insulation, and lightweight concrete. - Plaster
Gypsum, lime, cement, or clay paste applied wet to walls and ceilings, hardening to a smooth, fire-resistant finish. - Quartz
Silica mineral (SiO2) and the engineered quartz surfaces made by bonding crushed quartz and other stone with resin. - Slag
Ground granulated blast-furnace slag, a hydraulic by-product of iron making used as a partial cement replacement in concrete. - Terra Cotta
Fired clay, typically red or buff, used for architectural cladding, ornament, and roof tile. - Vermiculite
Hydrated mica mineral that expands when heated, used as lightweight fill, fireproofing aggregate, and loose-fill insulation.
Code reference
Always verify the adopted code edition and local amendments for the project jurisdiction.
Governing editions
| Code or regulation | Edition cited |
|---|---|
| International Building Code (IBC) | 2024 |
| ACI 318 (as referenced by IBC 2024) | 318-19 |
| TMS 402 / TMS 602 (as referenced by IBC 2024) | 2022 |
Concrete
- IBC 2024, Section 1901.2: design per Chapter 19 and ACI 318 as supplemented by Section 1905
- IBC 2024, Section 1901.5: construction documents state f'c at stated ages and rebar grade
- IBC 2024, Section 1901.7.1: cast-in-place tolerances per ACI 117 (precast per ACI ITG-7, Section 1901.7.2)
- IBC 2024, Section 1901.9: lightweight concrete: coarse aggregate saturated surface dry; w/cm 0.50 maximum (lightweight)
- IBC 2024, Section 1903.1: concrete materials and tests per the standards listed in ACI 318; 1903.2 GFRC per PCI 128; 1903.3 insulating concrete form material per ASTM E2634
- IBC 2024, Section 1904.1: structural concrete durability per ACI 318; R-2 and R-3 buildings up to 3 stories: f'c 3,000 psi minimum for basement, foundation, exterior, and weather-exposed vertical walls
- IBC 2024, Section 1904.2: nonstructural concrete minimum f'c 2,500 psi (F0), 3,000 psi (F1), 3,500 psi (F2, F3); air-entrained per ACI 318
- IBC 2024, Section 1905.6.2: no structural plain concrete in SDC C to F except footings and limited dwelling walls
- IBC 2024, Section 1907: slabs on ground at least 3-1/2 in. thick over a 6-mil polyethylene vapor retarder lapped at least 6 in. (exceptions for detached R-3 accessory structures, small unheated rooms, carports, and flatwork)
Masonry
- IBC 2024, Section 2101.2: masonry design per TMS 402, 403, or 404 (empirical design not permitted, Section 2101.2.3)
- IBC 2024, Section 2101.4: shear walls in running bond only
- IBC 2024, Section 2103.1: concrete, clay or shale, stone, glass unit, and AAC masonry units per TMS 602 Article 2.3; architectural cast stone per TMS 504
- IBC 2024, Section 2103.2: mortar per TMS 602 Articles 2.1 and 2.6 A; surface-bonding mortar ASTM C887; adhered veneer mortar TMS 402 Section 13.3
- IBC 2024, Section 2103.3: grout per TMS 602 Article 2.2
- IBC 2024, Section 2104.1.1: below-grade and elevator shaft walls solid grouted
- IBC 2024, Section 2104.1.2: corrugated metal brick ties not permitted
- IBC 2024, Sections 2104.1.6 and 2104.1.7: CMU control joints per NCMA TEK 10-2C or 10-3; brick expansion joints per BIA Technical Notes 18 and 18A
Glass
- IBC 2024, Section 2403.1: tempered glass permanently marked
- IBC 2024, Section 2403.3: framing deflection limit L/175 for edges to 13'-6", L/240 plus 1/4 in. for longer edges
- IBC 2024, Section 2404: wind load design per Section 1609 and ASTM E1300
- IBC 2024, Section 2406.2: safety glazing per CPSC 16 CFR 1201 or ANSI Z97.1 Class A; hazardous locations in Section 2406.4
- IBC 2024, Section 2407.1: glass in guards laminated fully tempered or heat-strengthened, 1/4 in. minimum
Gypsum and plaster
- IBC 2024, Section 2506: gypsum products identified by manufacturer and protected from weather; standards in Table 2506.2 (ASTM C1396, C1278, C1177, C1658, C474, C475)
- IBC 2024, Section 2508: installation per GA-216 or ASTM C840; gypsum wallboard and plaster not used on exposed exterior surfaces or where directly exposed to water or continuous high humidity
- IBC 2024, Section 2508 (Table 2508.6): gypsum diaphragm ceilings: 1/2 in. panels, 16 in. o.c. framing 90 plf, 24 in. o.c. 70 plf
- IBC 2024, Section 2509: tile backing in showers and water closets per Table 2509.2 (ASTM C1178, C1288, C1325); water-resistant gypsum backing not over a vapor retarder in shower or tub compartments
- IBC 2024, Section 2510: lath for cement plaster per ASTM C926 and C1063
- IBC 2024, Section 2512: exterior plaster three coats over lath, weep screed 0.019 in. minimum, 4 in. above earth or 2 in. above paved areas; cement plaster applied above 40°F
Referenced standards
| Standard | Edition | Required by | Applies to |
|---|---|---|---|
| ACI 318 / ACI 117 / ACI ITG-7 / PCI 128 / ASTM E2634 | 318-19; others not recorded | IBC 2024, 1901.2, 1901.7, 1903 | Concrete |
| TMS 402 / 403 / 404 / 602 / 504 | 2022 (402, 602); others not recorded | IBC 2024, 2101.2, 2103.1 | Masonry |
| ASTM C887 / NCMA TEK 10-2C / 10-3 / BIA TN 18, 18A | Not recorded | IBC 2024, 2103.2, 2104.1 | Mortar, CMU, brick joints |
| ASTM E1300 / ANSI Z97.1 / 16 CFR 1201 | Not recorded / Current CFR | IBC 2024, 2404, 2406.2 | Glass |
| ASTM C1396 / C1278 / C1177 / C1658 / C474 / C475 / C840 / GA-216 | Not recorded | IBC 2024, 2506, 2508 | Gypsum |
| ASTM C1178 / C1288 / C1325 | Not recorded | IBC 2024, 2509 | Tile backing |
| ASTM C926 / C1063 | Not recorded | IBC 2024, 2510 | Cement plaster lath |
Sources
- UpCodes: 2024 IBC Chapter 19 concrete, https://up.codes/viewer/department-of-defense/ibc-2024/chapter/19/concrete
- UpCodes: 2024 IBC Chapter 21 masonry, https://up.codes/viewer/department-of-defense/ibc-2024/chapter/21/masonry
- UpCodes: 2024 IBC Chapter 24 glass and glazing, https://up.codes/viewer/department-of-defense/ibc-2024/chapter/24/glass-and-glazing
- UpCodes: 2024 IBC Chapter 25 gypsum board, gypsum panel products and plaster, https://up.codes/viewer/department-of-defense/ibc-2024/chapter/25/gypsum-board-gypsum-panel-products-and-plaster