Accessible Toilet Rooms and Plumbing Fixtures


Summary

Accessible toilet rooms provide turning space, an accessible stall with grab bars, a lavatory, and fixtures at set heights, and drinking fountains come in a high and low pair. Toilet rooms are tight, dimension-driven spaces, so draw the fixture clearances and door swings before sizing the room.


Cols

Scope

Terminology

Requirements

Toilet rooms

Water closets and compartments

Urinals and lavatories

Showers, tubs, and grab bars

Drinking fountains

Worked examples

Wheelchair accessible stall

A wall-hung water closet in the accessible compartment.

Step Requirement Result
Compartment size 60 in. wide by 56 in. deep Plan 5 ft by 4 ft 8 in. clear
Centerline 16 in. to 18 in. from the side wall 17 in. typical
Side grab bar 42 in. long, 33 in. to 36 in. high Mounted beside the water closet
Rear grab bar 36 in. long Behind the water closet
Door Not into fixture clearance Swing outward or into the turning space

Fixture count

A public toilet room has six compartments.

Step Requirement Result
Wheelchair accessible compartment At least one 1
Second accessible compartment Six or more compartments 1 ambulatory accessible compartment
Lavatory At least one not in a compartment 1 at 34 in. maximum

Drinking fountains

Step Requirement Result
Minimum Two fountains One high-low pair
Six fountains total 50 percent each type 3 for wheelchair users and 3 for standing persons

Coordination

Common issues

Standards

Sources