An accessible route is a continuous, unobstructed path of travel that connects accessible elements and spaces, from site arrival points through entrances to every accessible space. Route width, slope, surface, and protruding objects are checked on plan, section, and elevation, so lay out the route before placing rooms, walls, and furniture.


Cols

Scope

Terminology

Requirements

Where routes are required

Walking surfaces

Surfaces and changes in level

Protruding objects

Worked examples

Corridor width check

A corridor is 44 in. wide with a drinking fountain recess and a door that opens into it.

Step Check Result
Clear width 44 in. against 36 in. minimum Complies
Passing space Corridor under 60 in. wide 60 in. by 60 in. passing space every 200 ft maximum
Length 300 ft One passing space near the middle Passing space at 150 ft or earlier
Door swing Door reduces the clear width when open Keep the swing clear of the 36 in. width

Sidewalk slope

A walk rises 18 in. over 30 ft.

Step Calculation Result
Run in inches 30 × 12 360 in.
Slope 18 ÷ 360 0.05, or 1:20
Check 1:20 maximum for a walking surface At the limit; steeper requires a ramp

Protruding object

A wall-mounted fire extinguisher cabinet projects 6 in. at a height of 48 in. along a corridor.

Step Check Result
Height 48 in. is between 27 in. and 80 in. Limit applies
Projection 6 in. against 4 in. Exceeds the limit
Fix Recess the cabinet or add a cane-detectable element Projection 4 in. or less, or cabinet bottom at 27 in. or lower