Reach Ranges and Clear Floor Space


Summary

The building blocks of accessible design are a 60 in. turning space, a 30 in. by 48 in. clear floor space at each element, knee and toe clearance under sinks and counters, and controls within a 15 in. to 48 in. reach range. Every accessible element uses these blocks, so check them on every plan, interior elevation, and section.


Cols

Scope

Terminology

Requirements

Turning and floor space

Knee and toe clearance

Reach ranges

Operable parts

Worked examples

Switch and outlet heights

Element Reach Result
Light switch, unobstructed side reach 15 in. to 48 in. Mount the top of the switch plate at 48 in. or lower
Receptacle, unobstructed 15 in. minimum Bottom of the outlet at 15 in. or higher
Thermostat Operable part Within 15 in. to 48 in.

Reach over a counter

A switch is mounted above a 24 in. deep counter at 34 in. high.

Step Requirement Result
Obstruction 34 in. high, 24 in. deep Obstructed side reach
Maximum reach 46 in. for depth up to 24 in. Mount the switch at 46 in. or lower
If the counter were 10 in. deep 48 in. maximum Switch up to 48 in.

Sink knee clearance

A kitchen sink for a wheelchair user.

Step Requirement Result
Clear floor space 30 in. by 48 in. forward approach Leave 30 in. by 48 in. at the sink
Knee clearance 9 in. to 27 in. high; 30 in. wide; 11 in. deep at 9 in. Open cabinet or removable base
Toe clearance 17 in. to 25 in. deep Floor to 9 in. open