Accessible Dwelling Units


Summary

Housing and lodging are covered by three overlapping rules: the Fair Housing Act for multifamily housing, the building code's Type A and Type B dwelling unit provisions, and the ADA Standards for hotel guest rooms. The covered units, the number of accessible units, and the features differ by rule, so identify the rules that apply before laying out units.


Cols

Scope

Terminology

Requirements

Fair Housing Act

Building code Type A and Type B units

Transient lodging (ADA)

Total guest rooms Rooms with mobility features Of those, with roll-in showers
1 to 25 1 0
26 to 50 2 0
51 to 75 4 1
76 to 100 5 1
101 to 150 7 2
151 to 200 8 2
201 to 300 10 3
301 to 400 12 4
401 to 500 13 4
501 to 1,000 3 percent of total 1 percent of total
1,001 and over 30, plus 2 for each 100 over 1,000 10, plus 1 for each 100 over 1,000

Worked examples

120-room hotel

Step Source Result
Rooms with mobility features Table 224.2, 101 to 150 rooms 7 rooms
With roll-in showers Same row 2 of the 7
Without roll-in showers 7 − 2 5 rooms with tub or transfer shower
Communication features Table 224.4, 101 to 150 rooms 12 rooms

24-unit apartment building with an elevator

Step Rule Result
FHA Four or more units, elevator All 24 units covered
Type A 2 percent of 24 = 0.48, minimum one 1 Type A unit
Type B Four or more units All units Type B unless reduced
Entrance and common areas Accessible route to every covered unit Show on the site and floor plans

Walk-up building without an elevator

Six units, three floors, no elevator.

Step Rule Result
Covered units Ground-floor units only 2 ground-floor units
Features Seven requirements in each covered unit Accessible entrance, route, switches, bath blocking, kitchen
Upper floors Not covered by the FHA Local code may still require them

Coordination

Common issues

Standards

Sources